LLP108 Providence new
1050mm x 250mm (41.3" x 9.85")
LLP113 Cambridge new
1050mm x 250mm (41.3" x 9.85")
LLP109 Stamford new
1050mm x 250mm (41.3" x 9.85")
LLP111 Boston new
1050mm x 250mm (41.3" x 9.85")
LLP110 Burlington new
1050mm x 250mm (41.3" x 9.85")
LLP112 Hartford new
1050mm x 250mm (41.3" x 9.85")
BS 7976 (dry) BS 7976 (wet) DIN 51130 DIN 51097 LRV
61 33 R10 B 31
BS 7976 (dry) BS 7976 (wet) DIN 51130 DIN 51097 LRV
61 33 R10 B 30
BS 7976 (dry) BS 7976 (wet) DIN 51130 DIN 51097 LRV
61 33 R10 B 21
BS 7976 (dry) BS 7976 (wet) DIN 51130 DIN 51097 LRV
61 33 R10 B 12
BS 7976 (dry) BS 7976 (wet) DIN 51130 DIN 51097 LRV
61 33 R10 B 12
BS 7976 (dry) BS 7976 (wet) DIN 51130 DIN 51097 LRV
61 33 R10 B 16
LLP113 s
Standard Result
Thickness 4.5 mm
Wear layer 0.55 mm
Guarantee Light industrial
Commercial
Domestic
10 years*
12 years*
15 years*
Bevelled edge No
Standards EN 649 Pass
Classification EN 685- Light industrial
EN 685- Commercial
EN 685- Domestic
ASTM F1700
42: Light industrial general
33: Commercial heavy
23: Domestic heavy
Class III Type B
Reaction to fire EN 13501-1
EN ISO 9239-1
EN ISO 11925-2
ASTM E648-06
Bfl-s1
Pass
Pass
Class 1
Staining resistance EN 423
ASTM F925
Class 0
Pass
Light fastness EN ISO 105-B02
ASTM F1515
≥7
<8
Abrasion resistance EN 660-2
ASTM D3884
Group T
Pass
Dimensional stability EN 434
ASTM F2199
≤ 0.10%
Pass
Acoustic Impact noise reduction EN ISO 717-2 / EN ISO 140-8 rLw= 13 db
Electrical behaviour body voltage EN 1815 Pass
Indentation - residual EN 433
ASTM F1914
≤ 0.1mm
<8%
Castor chair continuous use EN 425 Pass
Thermal conductivity ISO 8302 0.0245 m²K/W
Suitable for underfloor heating. Max 27°C
Slip resistance BS 7976
DIN 51130
DIN 51097
EN 13893
ASTM C1028
See individual product
See individual product
See individual product
DS
ADA Compliant
Light reflectance value BS 8493:2008+A1:2010 See website for LRV results
Adhesive Please refer to our installation instructions
Recycling Suitable
Technical Information
18